Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Am J Clin Pathol ; 161(3): 212-215, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37878771

RESUMO

OBJECTIVES: To determine the impact of residual platelets on dilute Russell's viper venom time (DRVVT) assay in frozen-thawed plasma submitted for lupus anticoagulant (LAC) testing. METHODS: We measured platelet counts in frozen-thawed samples submitted for LAC testing and evaluated the association between platelet count and the DRVVT screening time and ratios. We also spiked platelets into a LAC-positive sample to observe the effect on the DRVVT. RESULTS: Progressive increase in platelet count resulted in a statistically significant shortening of the DRVVT assay results on plasma after 1 freeze-thaw cycle. A similar effect was noted on the LAC-positive sample. CONCLUSIONS: Residual platelets in plasma samples result in shortening of DRVVT assay after 1 freeze-thaw cycle. This may result in a false-negative LAC test result.


Assuntos
Síndrome Antifosfolipídica , Inibidor de Coagulação do Lúpus , Humanos , Tempo de Protrombina , Testes de Coagulação Sanguínea , Contagem de Plaquetas , Tempo de Tromboplastina Parcial
2.
Am J Clin Pathol ; 154(5): 671-682, 2020 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-32686817

RESUMO

OBJECTIVES: Despite more than 40 years of experience performing the Bethesda assay (BA), poor intra- and interlaboratory precision remains the biggest laboratory challenge to date. METHODS: The BA procedure was modeled using stochastic simulation techniques to determine the precision of the BA up to dilutions of 1:4,096, to estimate the minimum significant relative change at various inhibitor titers, and to understand the laboratory procedural variables that could significantly affect the performance of the BA at high dilutions. RESULTS: Selecting the lowest dilution tube with a residual activity closest to 25% for calculating the reported Bethesda titer (BT), using a factor activity assay with a coefficient of variation less than or equal to 7.5% in the range of 15% to 50% factor activity level, performing the factor activity measurement in replicates, and minimizing pipette volumetric error resulted in the lowest imprecision in the reported BT. The factor neutralization kinetics of the inhibitor appear to have little impact on the precision of the assay if the incubation time is greater than 90 minutes. CONCLUSIONS: This in silico model will assist future laboratory efforts in standardizing the quantification of specific coagulation factor inhibitors and improving the precision of the reported results.


Assuntos
Testes de Coagulação Sanguínea/normas , Simulação por Computador , Testes de Coagulação Sanguínea/métodos , Humanos , Sensibilidade e Especificidade
4.
Semin Thromb Hemost ; 40(1): 115-20, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24381152

RESUMO

Warfarin dosing relies on accurate measurements of international normalized ratio (INR), which is calculated from the prothrombin time (PT), International Sensitivity Index international sensitivity index (ISI) of the thromboplastin, and the geometric mean of normal PT (MNPT). However, ISI assignments of certain reagent/instrument combinations are frequently unavailable, especially when the reagent and instrument are not from the same manufacturer. The effort to be in compliance with widely endorsed Clinical and Laboratory Standards Institute (CLSI) guidelines by locally verifying or assigning an ISI to an unsupported reagent/instrument combination is further hindered by the lack of US Food and Drug Administration (FDA)-approved certified plasmas designated for a particular reagent/instrument combination. The objectives of the study include development of a process to verify/assign ISI and MNPT of a single thromboplastin reagent from one manufacturer across multiple instruments including several from another manufacturer and across several campuses of a single institution, the Mayo Clinic. In this study, RecombiPlasTin 2G (R2G), was evaluated on the ACL TOP 700 (IL), STA-R Evolution, STA Compact, and STA Satellite. Random normal donor samples (n = 25) were used to verify/assign MNPT. A subset of the normal donors (n = 8) and 13 warfarin pools (INR range: 1.3-3.9), created from stable warfarin patient plasma, were used for ISI verification/assignment. The manufacturer's assigned ISI was first verified on the ACL TOP 700 (reference method), then assigned on three unsupported instruments using orthogonal regression analysis. The MNPT and manufacturer assigned ISI (11.0, 0.95) were verified on the ACL TOP 700 and subsequently assigned on the STA-R Evolution (11.6, 1.04); STA Compact (11.5, 1.02); and STA Satellite (10.9, 0.99). Linear correlations of the INR results from all the four instruments demonstrated an r2 > 0.99. This process provides a reproducible approach to assigning ISIs on unsupported reagent/instrument combinations. Our data also confirm that ISIs of the same PT reagent differ significantly on different instruments, thus confirming the requirement for evaluations and validation of ISIs for different reagent/instrument combinations.


Assuntos
Anticoagulantes , Doadores de Sangue , Coeficiente Internacional Normatizado , Tempo de Protrombina , Varfarina , Anticoagulantes/administração & dosagem , Anticoagulantes/farmacocinética , Feminino , Humanos , Coeficiente Internacional Normatizado/instrumentação , Coeficiente Internacional Normatizado/métodos , Coeficiente Internacional Normatizado/normas , Masculino , Tempo de Protrombina/instrumentação , Tempo de Protrombina/métodos , Tempo de Protrombina/normas , Estados Unidos , Varfarina/administração & dosagem , Varfarina/farmacocinética
5.
Arterioscler Thromb Vasc Biol ; 31(11): 2760-6, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21852562

RESUMO

OBJECTIVE: Left atrial blood stasis is associated with increased risk for left atrial appendage thrombus (LAAT) and stroke in atrial fibrillation (AF). Von Willebrand factor (VWF) is associated with thromboembolism in AF. VWF thrombogenic activity is proportional to multimer size, which is regulated by VWF-cleaving protease (ADAMTS13). METHODS AND RESULTS: To assess the association between left atrial blood stasis and VWF-ADAMTS13 system, plasma VWF antigen (VWF:Ag), VWF activity (VWF:Act), and ADAMTS13 activity were measured in 414 consecutive patients with nonvalvular AF (age 63±13 years; 25% women) and in 100 patients (age 64±14 years; 39% women) with normal sinus rhythm. Spontaneous echocardiographic contrast (SEC), left atrial appendage emptying velocity, and LAAT were assessed by transesophageal echocardiography. Presence and intensity of SEC varied directly with VWF:Ag and VWF:Act but not with ADAMTS13 activity. AF patients with LAAT had higher VWF:Ag (200±61 versus 155±52, P=0.0006) and VWF:Act (179±57 versus 141±51 P=0.0026) compared with those without LAAT. VWF:Ag and VWF:Act were independent predictors of LAAT after adjustment for CHADS2 score (P=0.0179 and P=0.0497, respectively). CONCLUSION: The association between VWF and SEC may explain the thrombotic propensity in AF. Elevated VWF:Ag may help identify AF patients at risk for LAAT.


Assuntos
Proteínas ADAM/sangue , Fibrilação Atrial/sangue , Fibrilação Atrial/fisiopatologia , Átrios do Coração/fisiopatologia , Homeostase/fisiologia , Fator de von Willebrand/metabolismo , Proteína ADAMTS13 , Idoso , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/complicações , Biomarcadores/sangue , Estudos de Casos e Controles , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fluxo Sanguíneo Regional/fisiologia , Fatores de Risco , Tromboembolia/diagnóstico por imagem , Tromboembolia/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA